  bnc series ( 978 ) 927-1060 ? fax ( 978 ) 922-6430 ? www.deltarf.com p.o. box 53 ? 416 cabot st. ? beverly, ma 01915 bnc series coaxial connectors contents click on any line to go directly to the indicated page navigation guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 speci?ations and interface dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . 3 design features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 iso 9001 certified 2003 online catalog cable connectors straight cable plugs . . . . . . . . . 7 right angle cable plugs. . . . . . . 9 straight cable jacks . . . . . . . . . 11 bulkhead cable jacks . . . . . . . . 12 panel cable jacks . . . . . . . . . . . 14 receptacles panel jack receptacles . . . . . . . 16 right angle panel jack receptacles . . . . . . . 17 panel plug receptacles. . . . . . . 17 bulkhead jack receptacles . . . . 18 bulkhead plug receptacles. . . . 19 p.c. board receptacles . . . . . . . 20 stripline receptacles . . . . . . . . 20 pressmount receptacles. . . . . . 21 accessories resistive terminations . . . . . . . 22 dust caps. . . . . . . . . . . . . . . . . 22 in-series adapters . . . . . . . . . . 23 bnc75 (75 impedance) cable connectors. . . . . . . . . . . 25 receptacles . . . . . . . . . . . . . . . 26 in-series adapters . . . . . . . . . . 27 technical information mounting figures . . . . . . . . . . 28 cable groups . . . . . . . . . . . . . . 29 cable assembly instructions . . 30 assembly tooling . . . . . . . . . . . 33 ordering and warranty . . . . . . 34
delta electronics manufacturing ( 978 ) 927-1060 ?fax ( 978 ) 922-6430 ?www.deltarf.com 2 online catalog navigation guide we have con?ured this online catalog to take advantage of acrobat navigation shortcuts (links). however, these links are not visible on the pages?making them visible would compromise the pages readability. ? clicking on any entry in the table of contents will take you to the indicated page. ? shown below are the ?ot spots?on all of the product pages that will take you to background information on various connector characteristics. ? after you use a link to jump to another page, you can use the ?ack?arrow in acrobats menu bar to return to the page you jumped from. ? con?ure acrobat reader to show bookmarks for a table of contents by speci? characteristic (for example, cable plugs broken out by cable attachment method). ? to ?d a speci? part number, use acrobats search feature. in addition, the pages are formatted to ? within the margins of standard laser or inkjet printers no need to use the ?hrink to ??option when printing pages from acrobat. click her e to go to the table of contents panel jack?ilitary clamp for flexible cable cable fig. dimensions mounting plating delta p/n group abc figure body contact 1 1 1.75 .63 .75 33 nickel silver 1011-001-n330 a/20 2, 3 1 1.75 .63 .75 33 nickel silver 1011-004-n330 a/20 5, 6 2 1.16 .55 .50 07 nickel silver ug-291c/u a/17 figure 1 figure 2 c dia. a b a b c dia. assembly procedure/ trim code click here to jump to a guide to delta cable groups. click here to jump to dimensions for delta mounting ?ures. click here to jump to the cable assembly procedure for this connector. delta electronics manufacturing bnc cable jacks click on the delta logo on any page to jump to the table of contents. click on the page title to jump to speci?ations and interface dimensions. click here to go to deltas website if your computer is con?ured for web connection via acrobat.
delta electronics manufacturing ( 978 ) 927-1060 ?fax ( 978 ) 922-6430 ?www.deltarf.com 3 bnc connectors electrical: nominal impedance: 50 ohms. frequency range: dc? ghz. voltage rating: 500 volts rms. dielectric withstanding voltage : 1,500 vrms. insulation resistance: 5,000 megohms. materials/finishes: insulators: te?n per astm-d-1710. male contacts: brass per astm-b-16. female contacts: beryllium copper per astm-b-196. contact plating : silver per qq-s-365, or gold per mil-g-45204. gaskets: silicone rubber per zz-r-765, class ii, grade 50. other metal parts: brass per astm-b-16, plated: silver per qq-s-365, or nickel per qq-n-290. all other speci?ations are in accordance with the latest issues of mil-prf-39012, or mil-a-55339, or other applicable mil speci?ations, and interfaces are in accordance with mil-std-348. *these speci?ations are typical and may not apply to all connectors. detailed speci?ations for individual connec- tors are available on request. general description delta bnc connectors are compact, economical, 50 impedance connectors with two-stud bayonet coupling. they are best suited for use with cables in the range of .150" to .250" diameter, but are available for other cables from .090" to over .75" diameter. M39012 qpl bnc connectors and m55339 qpl bnc adapters are also included in this section. our extensive line of bnc receptacles includes con?urations for virtually any packaging requirement, and we can supply any adapter or accessory you may need to complete your system design. as with our other connector series, deltas customer-driven design results in bnc series connectors with practical and unique features that make your design and assembly process easier. some of these include: heli-grip cable connectors for fast, reliable assembly to ?xible cable without special tooling. pressmount receptacles (page 21) mount securely in a single round hole, saving space on your components and reducing your housing fabrication costs. panel receptacles with ?nge sizes to match the same hole pattern as standard sma or type n connectors, letting you drill one hole pattern and mount bnc, n, sma, tnc, or 7/16 series connectors as needed. isolated ground receptacles (see page 19). 75 impedance bnc connectors (see page 25) for matched-impedance applications. our bnc series product line is still growing, so please call if you dont see what you need. for adapters between bnc and other series, download the document deltaabs.pdf from our website. bnc speci?ations* *slotted and flared to meet gage requirements of mil-prf-39012/16. .190 min. *see below .385 .390 179 181 .463 .473 .006 min. .003 min. .208 .228 .210 .230 .322 max. .081 .087 .091 .097 reference plane plug interface** reference plane .188 .208 .186 max. .256 max. .186 .206 .414 min. .319 .321 .327 .333 .346 .356 .081 .087 .327 .335 .015 .030 .075 .081 .006 max. .204 .208 .378 .382 .432 .436 179 181 jack interface** **some proportions altered to illustrate detail.
delta electronics manufacturing ( 978 ) 927-1060 ?fax ( 978 ) 922-6430 ?www.deltarf.com 4 design features about deltas customer-driven design at delta, customer-driven design isnt just a catchy slogan. it means that we make rf connectors that help you build your products ef?iently, quickly, and cost-effectively. because we design for your needs, nobody else can offer you such a broad line of standard connectors, along with an ever-growing list of innovative, user-friendly design variations like those detailed on these pages. these featured connector technologies grew out of real-world requirements, and have saved our customers untold hours and dollars over the years. and there are thousands of other special connector designs we?e produced that we dont have space to include in this catalog. so if you dont see the exact connector con?uration you need, please call us?e may have already made it. if not, we?l work with you to provide the the connectors you need, with the best price/performance balance in the business, and with quality and delivery that will enhance your products and production schedules. plating options for economy and performance (albaloy or nickel?vailable for all connector series except sma) silver plating has long been standard on rf connectors with brass bodies, but its high cost and low corrosion resistance make it less than ideal in most applications. nickel plating is less expensive and more durable than silver, and is standard on many of our connectors. however, in some applications, nickel plating can introduce unwanted intermodulation dis- tortion, particularly on large size connectors. for these applications, we offer optional albaloy plating, a tin/zinc/copper composite with a bright white ?ish, the corrosion resis- tance of nickel, and the low intermodulation distortion of silver plating. albaloy plating has the same composition as, and is fully compatible with, other commer- cial platings designated sucoplate , ip-23, white bronze, and tri-alloy. to order a delta connector with plating other than the listed ?ish, substitute a , n , or q in the delta part number as below: for silver plating: 1111-111- a 111. for nickel plating: 1111-111- n 111. for albaloy plating: 1111-111- q 111. note: M39012 and m55339 qpl connectors can only be supplied with the speci?d plating. sma connectors with stainless-steel bodies are available with gold plating or passivated ?ish. plating options................................................................................................................ ...4 panel receptacles with common ?nge sizes ...................................................................5 pressmount receptacles .....................................................................................................6 heli-grip connectors for ?xible cable .............................................................................6 design features
delta electronics manufacturing ( 978 ) 927-1060 ?fax ( 978 ) 922-6430 ?www.deltarf.com 5 design features does it make sense that you have to drill your components with different mounting hole patterns whenever you need to ship them with a different connector series attached? we didnt think so, either. thats why we offer a wide range of connectors in different series with common ?nge sizes and contact/insulator con?urations. now you can streamline your production process and shorten your delivery cycle?ust predrill your components with one mounting hole pattern, and ship them with the connectors your customers require. flange sizes and available interfaces 1 2 " square ?nge (delta mounting ?ure 05)?tandard ?nge size for sma bnc n sma tnc 11 16 " square ?nge (delta mounting ?ure 09)?tandard ?nge size for bnc, tnc 1" square ?nge (delta mounting ?ure 33)?tandard ?nge size for type n .500 square .340 ( l ) typ. c .102 dia. typ. 1.00 square .718 ( l ) typ. c .125 dia. typ. bnc n sma tnc 7/16 contact and insulator con?urations are shown for illustration only?hese connectors are available with a wide variety of post, tab, solder pot, or slotted contacts. standard con?urations are shown on product pages, and your request for a custom design is always welcome. common flange sizes simplify your production (available on bnc, n, sma, tnc, and 7/16 series connectors as noted in product pages) .687 square .500 ( l ) typ. c .125 dia. typ. bnc n sma tnc
delta electronics manufacturing ( 978 ) 927-1060 ?fax ( 978 ) 922-6430 ?www.deltarf.com 6 design features delta pressmount receptacles delta pressmount receptacles eliminate the need for complicated mounting hole patterns and mounting hard- ware. they are simply pressed into a single through hole, and can be used in component housings as small as the outer diameter of the connector. an integral shoulder provides a positive depth stop during mounting. besides the standard types shown below and in the product pages, pressmount receptacles are available with a wide variety of contact and insulator con?urations?lease call if you dont see what you need. component housing internal circuitry knurl shoulder connector design as mounted on component standard bnc pressmount receptacles bnc jack (solder pot or post contact?age 21) bnc plug (post contact page 21) heli-grip cable attachment?or flexible cable with their reduced parts count and rapid assembly, deltas heli-grip connectors offer you signi?ant time savings in your cable assembly operation, without the need for dedicated crimp tools. heli-grip connectors all have captivated contacts, and assembly is easy?imply trim the cable, slide the trimmed cable into the cone/insulator/contact assembly (left), solder the center conductor to the contact, and screw the body assembly (right) onto the backend assembly. heli-grip connectors have cable retention strength greater than the force required to tear the cable braid. (proportions altered to illustrate detail) cable assembled to hardware subassembly backnut; cone/contact/ insulator subassembly as assembled in connector standard bnc heli-grip con?urations straight plug?age 8 right angle plug?age 10 straight jack?age 11 bulkhead jack?age 13 panel jack?age 15
delta electronics manufacturing ( 978 ) 927-1060 ?fax ( 978 ) 922-6430 ?www.deltarf.com 7 bnc cable plugs (c) in contact plating column indicates captive contact. straight plug?older-clamp for semi-rigid cable straight plug?ilitary clamp for flexible cable cable figure dimensions plating delta p/n assembly procedure/ group a b body contact trim code 1 1 1.16 .56 nickel silver 1001-001-n000-1 c/06 2, 3 1 1.66 .75 nickel silver ug-959a/u a/01 2, 3 1 1.66 .75 silver gold ( c ) M39012/16-0225 a/01 5, 6 2 1.03 .44 nickel silver ug-88/u c/04 5, 6 2 1.06 .50 nickel silver ug-88c/u a/17 5, 6 2 1.06 .50 nickel silver ug-88e/u a/17 5, 6 2 1.06 .50 nickel gold ( c ) 1001-015-n001 a/17 5, 6 2 1.06 .50 silver gold ( c ) M39012/16-0101 a/17 7 2 1.03 .44 nickel silver ug-260/u c/04 7 2 1.06 .50 nickel silver ug-260b/u a/17 7 2 1.06 .50 nickel silver ug-260d/u a/17 7 2 1.06 .50 nickel silver ( c ) 1001-021-n001 a/17 7 2 1.06 .50 silver gold ( c ) M39012/16-0102 a/17 8a 2 1.06 .50 nickel silver ug-1033c/u a/17 8a 2 1.06 .50 nickel silver ( c ) 1001-029-n001 a/17 8a 2 1.06 .50 silver gold ( c ) M39012/16-0103 a/17 8b 2 1.06 .50 nickel silver 1001-043-n000 a/17 8b 2 1.06 .50 nickel silver ( c ) 1001-043-n001 a/17 9 2 1.06 .50 nickel silver 1001-036-n000 a/18 9 2 1.06 .50 nickel silver ( c ) 1001-036-n001 a/18 9 2 1.06 .50 silver gold ( c ) M39012/16-0220 a/37 11 2 1.06 .50 nickel silver 1001-038-n000 a/18 22 2 1.06 .50 silver gold ( c ) M39012/16-0118 a/17 23 2 1.06 .50 silver gold ( c ) M39012/16-0111 a/17 25 2 1.06 .50 nickel silver 1001-132-n000 a/17 figure 1 figure 2 b dia. a b dia. a cable figure dimensions plating delta p/n assembly procedure/ group a b body contact trim code 13 1 1.06 .50 nickel* silver 1001-031-n003 f/08 14 1 1.06 .50 nickel* silver 1001-025-n003 f/07 figure 1 b dia. a * solder ferrule is gold plated.
straight plug?eli-grip for flexible cable straight plug?rimp type for flexible cable cable figure dimensions plating delta p/n assembly procedure/ group a b body contact trim code 5, 6 1 1.06 .50 nickel silver ( c ) 1001-018-n005 e/03 rg-223 1 1.06 .50 nickel silver ( c ) 1001-015-n005-3 e/03 7 1 1.06 .50 nickel silver ( c ) 1001-019-n005 e/03 8a 1 1.06 .50 nickel silver ( c ) 1001-029-n005-1 e/03 8b 1 1.06 .50 nickel silver ( c ) 1001-043-n005 e/03 9 1 1.06 .50 nickel silver ( c ) 1001-037-n005 e/03 10 1 1.06 .50 nickel silver ( c ) 1001-100-n005 e/03 11 1 1.06 .50 nickel silver ( c ) 1001-038-n005 e/03 figure 1 b dia. a heli-grip cable attachment these connectors have captivated contacts and allow rapid, easy assembly?imply trim the cable, slide into the cone/insulator/contact assembly (left), solder the center conductor to the contact, and screw body assembly (right) onto cable assembly. cable figure dimensions plating delta p/n assembly procedure/ group a b body contact trim code 3a, 4 1 1.72 .63 nickel gold ( c ) 1003-005-n000 b/11 5 2 1.09 .50 nickel gold 1003-017-n000 b/18 5 2 1.10 .50 nickel gold ( c ) 1003-017-n00e-2 b/19 6 2 1.09 .50 nickel gold 1003-013-n000 b/18 6 2 1.10 .50 nickel gold ( c ) 1003-013-n00e b/19 7 2 1.09 .50 nickel gold 1003-020-n000-2 b/18 7 2 1.10 .50 nickel gold ( c ) 1003-019-n00e-2 b/19 7 2 1.05 .41 nickel silver 1003-020-n000-5 * *** 7 2 1.05 .41 nickel gold 1003-020-n000-6 * *** 7 2 1.05 .50 nickel silver ( c ) 1003-020-n001-5 * *** 7 2 1.05 .50 nickel gold ( c ) 1003-020-n001-9 * *** 9 2 .94 .31 nickel silver ( c ) 1003-037-n000 b/20 figure 1 a b (crimp sleeve) figure 2 a b (crimp sleeve) except rg-223/u. * crimp center contact. delta electronics manufacturing ( 978 ) 927-1060 ?fax ( 978 ) 922-6430 ?www.deltarf.com 8 bnc cable plugs (c) in contact plating column indicates captive contact. ***contact factory for cable assembly instructions.
(c) in contact plating column indicates captive contact. right angle plug?ilitary clamp for flexible cable cable figure dimensions plating delta p/n assembly procedure/ group a b c body contact trim code 1 1 1.23 1.92 .75 nickel gold 1004-001-n000 a/07 2, 3 1 1.23 1.92 .75 nickel silver 1004-004-n000 a/07 5, 6 2 1.09 1.61 .50 nickel silver ug-913/u a/17 5, 6 2 1.09 1.61 .50 nickel silver ug-913a/u a/17 5, 6 2 1.09 1.61 .50 nickel silver ( c ) 1004-015-n001 a/17 5, 6 2 1.09 1.61 .50 silver gold ( c ) M39012/20-0101 a/17 5, 6 3 1.25 1.06 .44 nickel silver ( c ) 1005-014-n000 c/05 7 2 1.09 1.61 .50 nickel silver 1004-021-n000 a/17 7 2 1.09 1.61 .50 nickel silver ( c ) 1004-021-n001 a/17 7 2 1.09 1.61 .50 silver gold ( c ) M39012/20-0102 a/17 7 3 1.25 1.06 .44 nickel silver ( c ) 1005-021-n000-1 c/05 8a 3 1.25 1.06 .44 nickel silver ( c ) 1005-029-n000 c/05 8b 2 1.09 1.61 .50 nickel silver 1004-043-n000 a/17 9 2 1.09 1.61 .50 nickel silver 1004-036-n000 a/18 9 3 1.25 1.06 .44 nickel silver ( c ) 1005-036-n000 c/05 22 2 1.09 1.61 .50 silver gold ( c ) M39012/20-0108 a/17 figure 1 figure 2 c dia. b a c dia. b a figure 3 c dia. b a right angle plug?older-clamp for semi-rigid cable cable figure dimensions plating delta p/n assembly procedure/ group a b c body contact trim code 13 1 1.09 1.61 .50 nickel* silver 1004-031-n003 f/08 14 1 1.09 1.61 .50 nickel* silver 1004-025-n003 f/07 figure 1 c dia. b a * solder ferrule is gold plated. delta electronics manufacturing ( 978 ) 927-1060 ?fax ( 978 ) 922-6430 ?www.deltarf.com 9 bnc cable plugs
right angle plug?rimp type for flexible cable right angle plug?eli-grip for flexible cable cable figure dimensions plating delta p/n assembly procedure/ group a b c body contact trim code 5, 6 1 1.09 1.61 .50 nickel silver ( c ) 1004-018-n005 e/03 rg-223 1 1.09 1.61 .50 nickel silver ( c ) 1004-015-n005 e/03 7 1 1.09 1.61 .50 nickel silver ( c ) 1004-019-n005 e/03 8a 1 1.09 1.61 .50 nickel silver ( c ) 1004-029-n005 e/03 8b 1 1.09 1.61 .50 nickel silver ( c ) 1004-043-n005 e/03 9 1 1.09 1.61 .50 nickel silver ( c ) 1004-037-n005 e/03 10 1 1.09 1.61 .50 nickel silver ( c ) 1004-100-n005 e/03 11 1 1.09 1.61 .50 nickel silver ( c ) 1004-038-n005 e/03 figure 1 c dia. b a except rg-223/u. cable figure dimensions plating delta p/n assembly procedure/ group a b c body contact trim code 5 1 1.03 1.71 .50 nickel gold ( c ) 1007-017-n000-3 b/02 6 1 1.03 1.71 .50 nickel silver 1007-015-n000 b/02 7 1 1.03 1.71 .50 nickel gold 1007-019-n000-1 b/02 figure 1 c (crimp sleeve) b a heli-grip cable attachment these connectors have captivated contacts and allow rapid, easy assembly?imply trim the cable, slide into the cone/insulator/contact assembly (left), solder the center conductor to the contact, and screw body assembly (right) onto cable assembly. delta electronics manufacturing ( 978 ) 927-1060 ?fax ( 978 ) 922-6430 ?www.deltarf.com 10 bnc cable plugs (c) in contact plating column indicates captive contact.
heli-grip for flexible cable crimp type for flexible cable solder-clamp for semi-rigid cable military clamp for flexible cable straight jacks?or flexible and semi-rigid cable cable figure dimensions plating delta p/n assembly procedure/ group a b body contact trim code 2, 3 1 1.75 .75 nickel silver 1008-004-n000 a/20 5, 6 2 1.16 .50 nickel silver ug-89c/u a/17 5, 6 2 1.16 .50 nickel gold ( c ) 1008-015-n001 a/17 5, 6 2 1.16 .50 silver gold ( c ) M39012/17-0101 a/17 7 2 1.16 .50 nickel silver ug-261c/u a/17 7 2 1.16 .50 nickel silver ( c ) 1008-021-n001 a/17 7 2 1.16 .50 silver gold ( c ) M39012/17-0102 a/17 8a 2 1.16 .50 silver gold ( c ) M39012/17-0103 a/17 9 2 1.16 .50 nickel silver 1008-036-n000 a/18 9 2 1.16 .50 nickel silver ( c ) 1008-036-n001 a/18 11 2 1.16 .50 nickel silver 1008-038-n000 a/18 22 2 1.16 .50 silver gold ( c ) M39012/17-0118 a/17 23 2 1.16 .50 silver gold ( c ) M39012/17-0111 a/17 5, 6 2 1.16 .50 nickel silver ( c ) 1008-018-n005-1 e/03 rg-223 2 1.16 .50 nickel silver ( c ) 1008-015-n005 e/03 7 2 1.16 .50 nickel silver ( c ) 1008-019-n005 e/03 8a 2 1.16 .50 nickel silver ( c ) 1008-029-n005 e/03 8b 2 1.16 .50 nickel silver ( c ) 1008-043-n005 e/03 9 2 1.16 .50 nickel silver ( c ) 1008-037-n005 e/03 10 2 1.16 .50 nickel silver ( c ) 1008-100-n005 e/03 11 2 1.16 .50 nickel silver ( c ) 1008-038-n005-2 e/03 5 3 1.16 .50 nickel gold 1010-017-n000-1 b/05 6 3 1.16 .50 nickel gold 1010-013-n000 b/05 7 3 1.16 .50 nickel gold 1010-020-n000 b/05 7 3 1.06 .41 nickel silver 1010-020-n001-1 ** *** 13 2 1.16 .50 nickel* silver 1008-031-n003 f/08 14 2 1.16 .50 nickel* silver 1008-025-n003 f/07 *solder ferrule is gold plated. figure 1 figure 2 b dia. a b dia. a except rg-223/u. figure 3 a b delta electronics manufacturing ( 978 ) 927-1060 ?fax ( 978 ) 922-6430 ?www.deltarf.com 11 bnc cable jacks (c) in contact plating column indicates captive contact. **indicates crimp center contact. ***contact factory for cable assembly instructions.
bulkhead jacks?ilitary clamp for flexible cable cable fig. dimensions mounting max. plating delta p/n group abc figure panel body contact 2, 3 1 1.55 .92 .75 51 .11 nickel gold ( c ) 1016-004-n511 a/20 5, 6 2 1.16 .68 .50 59 .11 nickel silver ug-909/u a/17 5, 6 2 1.16 .68 .50 59 .11 nickel silver ug-909a/u a/17 5, 6 2 1.16 .81 .50 59 .24 nickel silver ug-909b/u a/17 5, 6 2 1.16 .81 .50 59 .24 silver gold ( c ) M39012/19-0101 a/17 5, 6 2 1.16 .68 .50 59 .11 nickel gold ( c ) 1016-015-n591 a/17 5, 6 3 1.14 .55 .44 57 .09 nickel silver 1017-014-n570 c/04 7 2 1.16 .68 .50 59 .11 nickel silver ug-910/u a/17 7 2 1.16 .68 .50 59 .11 nickel silver ug-910a/u a/17 7 2 1.16 .81 .50 59 .24 nickel silver ug-910b/u a/17 7 2 1.16 .81 .50 59 .24 silver gold ( c ) M39012/19-0102 a/17 7 2 1.16 .68 .50 59 .11 nickel silver ( c ) 1016-021-n591 a/17 7 4 1.14 .55 .44 57 .09 nickel silver ug-624/u c/04 8a 2 1.16 .81 .50 59 .24 silver gold ( c ) M39012/19-0110 a/17 9 2 1.16 .68 .50 59 .11 nickel silver 1016-036-n590 a/18 9 2 1.16 .68 .50 59 .11 nickel silver ( c ) 1016-036-n591 a/17 9 2 1.16 .81 .50 59 .24 silver gold ( c ) M39012/19-0220 a/17 11 2 1.16 .68 .50 59 .11 nickel silver 1016-038-n590 a/18 11 2 1.16 .68 .50 59 .11 nickel silver ( c ) 1016-038-n591 a/18 22 2 1.16 .81 .50 59 .24 silver gold ( c ) M39012/19-0118 a/17 23 2 1.16 .81 .50 59 .24 silver gold ( c ) M39012/19-0111 a/17 figure 1 (rear mount) figure 2 (rear mount) c dia. a b 1.00 hex a b c dia. .687 hex figure 4 (front mount) c dia. a b .625 dia. figure 3 (front mount) c dia. a b .625 hex assembly procedure/ trim code delta electronics manufacturing ( 978 ) 927-1060 ?fax ( 978 ) 922-6430 ?www.deltarf.com 12 bnc cable jacks (c) in contact plating column indicates captive contact.
bulkhead jack?rimp type for flexible cable bulkhead jack?eli-grip for flexible cable cable fig. dimensions mounting max. plating delta p/n group abc figure panel body contact 5, 6 1 1.16 .81 .50 59 .24 nickel silver ( c ) 1016-018-n595 e/03 rg-223 1 1.16 .81 .50 59 .24 nickel silver ( c ) 1016-015-n595 e/03 7 1 1.16 .81 .50 59 .24 nickel silver ( c ) 1016-019-n595 e/03 8a 1 1.16 .81 .50 59 .24 nickel silver ( c ) 1016-029-n595 e/03 8b 1 1.16 .81 .50 59 .24 nickel silver ( c ) 1016-043-n595 e/03 9 1 1.16 .81 .50 59 .24 nickel silver ( c ) 1016-037-n595 e/03 10 1 1.16 .81 .50 59 .24 nickel silver ( c ) 1016-100-n595-2 e/03 11 1 1.16 .81 .50 59 .24 nickel silver ( c ) 1016-038-n595-2 e/03 figure 1 (rear mount) a b c dia. .687 hex assembly procedure/ trim code except rg-223/u. cable fig. dimensions mounting max. plating delta p/n group abc figure panel body contact 5 1 1.31 .68 .50 59 .11 nickel silver 1019-016-n590 b/21 6 1 1.31 .68 .50 59 .11 nickel silver 1019-013-n590 b/21 7 1 1.31 .68 .50 59 .11 nickel silver 1019-020-n590 b/22 figure 1 (rear mount) a b c (crimp sleeve) .687 hex assembly procedure/ trim code bulkhead jack?older-clamp for semi-rigid cable cable fig. dimensions mounting max. plating delta p/n group abc figure panel body contact 13 1 1.16 .81 .50 59 .24 nickel* silver 1016-031-n593 f/08 14 1 1.16 .81 .50 59 .24 nickel* silver 1016-025-n593 f/07 figure 1 (rear mount) a b c dia. .687 hex assembly procedure/ trim code heli-grip cable attachment these connectors have captivated contacts and allow rapid, easy assembly?imply trim the cable, slide into the cone/insulator/contact assembly (left), solder the center conductor to the contact, and screw body assembly (right) onto cable assembly. * solder ferrule is gold plated. delta electronics manufacturing ( 978 ) 927-1060 ?fax ( 978 ) 922-6430 ?www.deltarf.com 13 bnc cable jacks (c) in contact plating column indicates captive contact.
panel jack?ilitary clamp for flexible cable panel jack?older-clamp for semi-rigid cable cable fig. dimensions mounting plating delta p/n group abc figure body contact 1 1 1.75 .63 .75 33 nickel silver 1011-001-n330 a/20 2, 3 1 1.75 .63 .75 33 nickel silver 1011-004-n330 a/20 5, 6 2 1.16 .55 .50 07 nickel silver ug-291c/u a/17 5, 6 2 1.16 .55 .50 07 silver gold ( c ) M39012/18-0102 a/17 5, 6 2 1.16 .55 .50 07 nickel gold ( c ) 1011-015-n071 a/17 7 2 1.16 .55 .50 07 nickel silver ug-262c/u a/17 7 2 1.16 .55 .50 07 silver gold ( c ) M39012/18-0101 a/17 7 2 1.16 .55 .50 07 nickel silver ( c ) 1011-021-n071 a/17 8a 2 1.16 .55 .50 07 silver gold ( c ) M39012/18-0103 a/17 9 2 1.16 .55 .50 07 nickel silver 1011-036-n070 a/18 9 2 1.16 .55 .50 07 nickel silver ( c ) 1011-036-n071 a/38 9 2 1.16 .55 .50 07 silver gold ( c ) M39012/18-0220 a/38 11 2 1.16 .55 .50 07 nickel silver 1011-038-n070 a/18 11 2 1.16 .55 .50 07 nickel silver ( c ) 1011-038-n071 a/18 22 2 1.16 .55 .50 07 silver gold ( c ) M39012/18-0118 a/17 23 2 1.16 .55 .50 07 silver gold ( c ) M39012/18-0111 a/17 figure 1 figure 2 c dia. a b a b c dia. * solder ferrule is gold plated. assembly procedure/ trim code figure 1 a b c dia. cable fig. dimensions mounting plating delta p/n group abc figure body contact 13 1 1.16 .55 .50 07 nickel* gold 1011-031-n073 f/08 14 1 1.16 .55 .50 07 nickel* gold 1011-025-n073 f/07 assembly procedure/ trim code delta electronics manufacturing ( 978 ) 927-1060 ?fax ( 978 ) 922-6430 ?www.deltarf.com 14 bnc cable jacks (c) in contact plating column indicates captive contact.
panel jack?eli-grip for flexible cable cable fig. dimensions mounting plating delta p/n group abc figure body contact 5, 6 1 1.16 .55 .50 07 nickel silver ( c ) 1011-018-n075 e/03 rg-223 1 1.16 .55 .50 07 nickel silver ( c ) 1011-015-n075 e/03 7 1 1.16 .55 .50 07 nickel silver ( c ) 1011-019-n075 e/03 8a 1 1.16 .55 .50 07 nickel silver ( c ) 1011-029-n075 e/03 8b 1 1.16 .55 .50 07 nickel silver ( c ) 1011-043-n075 e/03 9 1 1.16 .55 .50 07 nickel silver ( c ) 1011-037-n075 e/03 10 1 1.16 .55 .50 07 nickel silver ( c ) 1011-100-n075 e/03 11 1 1.16 .55 .50 07 nickel silver ( c ) 1011-038-n075 e/03 assembly procedure/ trim code figure 1 a b c dia. except rg-223/u. heli-grip cable attachment these connectors have captivated contacts and allow rapid, easy assembly?imply trim the cable, slide into the cone/insulator/contact assembly (left), solder the center conductor to the contact, and screw body assembly (right) onto the cable assembly. panel jack?rimp type for flexible cable figure 1 a b c (crimp sleeve) cable fig. dimensions mounting plating delta p/n group abc figure body contact 5 1 1.22 .63 .50 09 nickel gold ( c ) 1055-017-n091 b/12 6 1 1.22 .63 .50 09 nickel gold ( c ) 1055-015-n091 b/12 7 1 1.22 .63 .50 09 nickel gold ( c ) 1055-019-n091 b/12 assembly procedure/ trim code delta electronics manufacturing ( 978 ) 927-1060 ?fax ( 978 ) 922-6430 ?www.deltarf.com 15 bnc cable jacks (c) in contact plating column indicates captive contact.
panel jack receptacles?quare flange figure dimensions mounting plating delta p/n ab cd figure body contact 1 1.06 .55 .050 . 18 nickel silver ( c ) ug-185/u 2 1.06 .63 .062 .090 07 nickel silver ( c ) ug-290a/u 2 1.06 .63 .043 .090 12 nickel silver ( c ) ug-447/u 2 1.06 .63 .062 .090 07 silver gold ( c ) M39012/22-0001 2 1.06 .63 .062 .090 09 nickel silver ( c ) 1013-000-n090 2 1.06 .63 .062 .090 10 nickel silver ( c ) 1013-000-n100 2 1.06 .63 .062 .090 18 nickel gold ( c ) 1013-000-n180 2 1.00 .75 .062 .080 18 nickel gold ( c ) 1013-000-f181 ** 3 1.06 .63 .062 .080 33 nickel silver ( c ) 1013-000-n330 4 .715 .090 .175 .375 09 nickel silver ( c ) 1058-000-n091 5 .750 .080 .590 .705 18 nickel gold ( c ) * 1058-000-n181-1 6 .750 .080 .590 .705 05 nickel gold ( c ) 1058-000-n051 figure 1 (turret contact) figure 5 (post contact) figure 6 (post contact, 1 / 2 " square ?nge, interchangeable with sma standard ?nge size) figure 4 (post contact) figure 2 (solder pot contact) a b c a b d c ( i.d. ) a d c b .161 dia. .050 dia. a d c b .275 dia. .085 dia. a d c b .161 dia. .050 dia. figure 3 (solder pot contact, 1" square ?nge, interchangeable with type n standard ?nge size) a b d c ( i.d. ) delta electronics manufacturing ( 978 ) 927-1060 ?fax ( 978 ) 922-6430 ?www.deltarf.com 16 bnc receptacles (c) in contact plating column indicates captive contact. *indicates epoxy-captivated contact. **insulator ?sh with rear of ?nge. flange #18 except with .125 dia. mounting holes. see page 4 for alternate body plating information.
panel plug receptacle?quare flange figure 1 (solder pot contact, 3 / 4 " square ?nge) figure 2 (solder pot contact, 1" square ?nge, interchangeable with type n standard ?nge size) a b d c ( i.d. ) a b d c ( i.d. ) figure dimensions mounting plating delta p/n ab cd figure body contact 1 1.19 .80 .062 .090 18 nickel silver ( c ) ug-1104a/u 2 1.19 .80 .062 .080 33 nickel silver ( c ) 1023-000-n330 figure dimensions mounting plating delta p/n ab cd figure body contact 1 1.09 .91 .61 .062 18 nickel silver ( c ) ug-535/u 1 1.06 .91 .65 .062 07 nickel silver ( c ) 1015-000-n070 1 1.06 .91 .65 .062 09 nickel gold ( c ) 1015-000-n090 2 1.22 .91 .61 .062 33 nickel silver ( c ) 1015-000-n330 right angle panel jack receptacle?quare flange figure 1 (solder pot contact) figure 2 (solder pot contact, 1" square ?nge, interchangeable with type n standard ?nge size) b c d ( i.d. ) a b c d ( i.d. ) a dummy receptacle b a dimensions mounting figure plating delta p/n a b body contact .75 .090 09 nickel 1063-000-n090 delta electronics manufacturing ( 978 ) 927-1060 ?fax ( 978 ) 922-6430 ?www.deltarf.com 17 bnc receptacles (c) in contact plating column indicates captive contact.
bulkhead jack receptacles figure dimensions max. mounting plating delta p/n abc panel figure body contact 1 1.06 .49 .062 .13 62 nickel silver ( c ) ug-625b/u 2 1.28 .60 .052 .19 75 nickel silver ( c ) ug-657/u 2 1.28 .60 .052 .19 75 nickel silver ( c ) ug-657a/u 1 1.06 .47 .062 .13 65 nickel silver ( c ) ug-1094/u 1 1.19 .47 .062 .26 65 nickel silver ( c ) ug-1094a/u 1 1.06 .49 .062 .13 62 silver gold ( c ) M39012/21-0001 1 1.19 .47 .062 .26 65 silver gold ( c ) M39012/21-0002 1 1.19 .47 .062 .26 62 silver gold ( c ) M39012/21-0003 3 1.20 .83 .062 .26 59 nickel silver ( c ) ug-911a/u 3 1.20 .83 .062 .26 59 silver gold ( c ) M39012/24-0001 4 1.20 .52 .062 .26 63 nickel silver ( c ) ug-912/u 4 1.33 .52 .062 .34 63 nickel silver ( c ) ug-912a/u 4 1.20 .52 .062 .26 63 silver gold ( c ) M39012/24-0002 5 .92 1.22 .59 .13 63 nickel silver ( c ) ug-1098/u 5 .92 1.34 .59 .25 63 nickel silver ( c ) ug-1098a/u 5 .92 1.22 .59 .13 62 nickel silver ( c ) ug-1174/u figure 1 (front mount) figure 4 (front mount, hermetically sealed, with mounting gasket) figure 3 (rear mount, hermetically sealed, with mounting gasket) figure 2 (front mount, pressurized [non- hermetic], with mounting gasket) a b c ( i.d. ) .500 dia. a b c ( i.d. ) .570 dia. a b c ( i.d. ) .687 dia. c ( i.d. ) a .594 dia. b b c .062 ( i.d. ) a .594 dia. figure 5 (right angle, solder pot contact) delta electronics manufacturing ( 978 ) 927-1060 ?fax ( 978 ) 922-6430 ?www.deltarf.com 18 bnc receptacles (c) in contact plating column indicates captive contact.
bulkhead jack receptacles with solder lug figure dimensions max. mounting plating delta p/n abc panel figure body contact 1 1.06 .75 .062 .17 59 nickel gold ( c ) 1021-000-n591 2 1.06 .50 .062 .17 59 nickel gold ( c ) 1020-000-f59g figure 1 (standard grounding) a b c ( i.d. ) .042 dia. grounding lug .625 dia. figure 2 (isolated ground) a b c ( i.d. ) .042 dia. grounding lug .562 hex isolated-ground receptacles primary insulator isolating insulator panel connector body mounting components grounding lug these receptacles feature an additional insulator between the main connector body and the bodys mounting surfaces, electrically isolating the ground signal of the circuit from the panel. the circuit ground signal is passed through the panel via the solder lug for termination inside the equipment. since they are not a triaxial connector design, isolated-ground receptacles can be used with any standard bnc plugs. bulkhead plug receptacle figure dimensions max. mounting plating delta p/n abc panel figure body contact 1 1.25 .69 .062 .16 65 nickel silver ( c ) 1024-000-n651 figure 1 (front mount) a b c ( i.d. ) delta electronics manufacturing ( 978 ) 927-1060 ?fax ( 978 ) 922-6430 ?www.deltarf.com 19 bnc receptacles (c) in contact plating column indicates captive contact.
receptacles for printed circuit boards figure dimensions max. board mounting plating delta p/n ab cd thickness figure body contact 1 .66 .040 .116 .040 .063 pcb01 nickel gold ( c ) 1058-000-n04p 1 1.27 .040 .116 .040 .063 pcb01 nickel gold ( c ) 1058-000-n04p-1 2 .65 .085 .250 .038 .125 pcb02 nickel gold ( c ) 1058-000-n13p 3 1.03 .050 .125 .160 .063 pcb03 nickel silver ( c ) 1067-000-n91p-1 4 1.06 .575 .116 .040 .063 pcb01 nickel gold ( c ) 1069-000-n03p 5 .95 .61 .250 .038 .125 pcb02 nickel gold ( c ) 1069-000-n13p figure 1 figure 4 figure 5 figure 3 figure 2 .500 sq. a c b .040 sq. typ. .400 typ. d dia. .687 sq. a c b .038 dia. typ. .500 typ. d dia. a c d b .040 sq. typ. .45 dia. .30 typ. .030 dia. .500 sq. a c b .040 sq. typ. .400 typ. d dia. a c b d dia. .687 sq. .038 dia. typ. .500 typ. stripline receptacles figure dimensions plating delta p/n a b c d e f g h body contact 1 .078 .31 .500 .063 .063 .22 .828 .375 nickel gold (c) 1056-000-n000 2 #2-56 .125 10 .734 .125 .010 .710 .125 nickel gold 1057-000-n000 figure 1 figure 2 .63 dia. socket contact e dia. x f deep 8 holes, a dia. x b deep c dia. b.c. g h .750 dia. d .085 dia. .120 dia. .875 dia. d dia. b.c. g h e c holes, a dia. x b deep f delta electronics manufacturing ( 978 ) 927-1060 ?fax ( 978 ) 922-6430 ?www.deltarf.com 20 bnc receptacles (c) in contact plating column indicates captive contact.
delta electronics manufacturing ( 978 ) 927-1060 ?fax ( 978 ) 922-6430 ?www.deltarf.com 21 bnc receptacles (c) in contact plating column indicates captive contact. pressmount receptacles figure dimensions min. mounting plating delta p/n ab panel hole body contact 1 .062 .050 .150 .312 ?001 dia. nickel silver ( c ) 1020-000-n911-1 2 .285 .062 .150 .312 ?001 dia. nickel silver ( c ) 1020-000-n911-2 3 .060 .050 .200 .450 ?001 dia. nickel gold ( c ) 1020-000-n911-13 4 .060 .050 .200 .450 ?001 dia. nickel gold ( c ) 1024-000-n911-4 figure 1 (post contact) .600 .175 a b dia. .43 dia. .316 dia. over knurl delta pressmount receptacles component housing internal circuitry these connectors eliminate the need for complicated mounting hole patterns and mounting hardware. they are simply pressed into a single through hole, and the precisely-engineered knurled mounting section provides retention strength far greater than normal mating and unmating forces. an integral shoulder provides a positive stop when mounting. pressmounts are available for a wide variety of delta connector series, and can be used in packages as small as the outer diameter of the connector body. figure 2 (solder pot contact) .600 .175 a b ( i.d. ) .083 dia. .43 dia. .316 dia. over knurl figure 3 (post contact) .600 .25 .625 dia. .454 dia. over knurl a b dia. figure 4 (plug type, post contact) .860 .25 .625 dia. .454 dia. over knurl a b dia.
dust caps resistive termination ( plug type ) resistor dimensions features plating delta p/n a b c body contact 51 ?%, 1 / 2 watt 1.25 3.50 .144 nickel gold ( c ) mx-554/u 51 ?%, 1 / 2 watt 1.41 3.50 .144 nickel silver ( c ) mx-554a/u 51 ?%, 1 / 2 watt 1.14 . . no chain nickel gold ( c ) 1031-000-n00a-3 51 ?%, 1 watt 1.50 4.50 .130 nickel silver ( c ) 1051-000-n000 51 ?%, 1 watt 1.39 . . no chain nickel silver ( c ) 1051-000-n00a-5 75 ?%, 1 / 2 watt 1.41 3.50 .144 nickel silver ( c ) 1031-000-n000-4 75 ?%, 1 / 2 watt 1.14 . . no chain nickel gold ( c ) 1031-000-n00a-1 75 ?%, 1 watt 1.39 . . no chain nickel silver ( c ) 1051-000-n00a-2 a b c ( i.d. ) a b c ( i.d. ) a b c ( i.d. ) figure dimensions features plating delta p/n a b c body contact 1 .67 2.25 .144 bead chain nickel cw-123a/u 1 .59 . . no chain nickel cw-155a/u 1 .69 2.25 .144 bead chain / shorting type nickel silver ( c ) cw-159/u 1 .67 2.25 .144 bead chain silver M39012/25-0006 1 .67 2.70 .52 safety chain silver M39012/25-0007 2 .69 3.25 .281 bead chain nickel cw-282/u 2 .69 3.25 .281 bead chain silver M39012/25-0008 2 .69 3.25 .281 safety chain silver M39012/25-0009 figure 1 (shown with bead chain) figure 2 (shown with safety chain) delta electronics manufacturing ( 978 ) 927-1060 ?fax ( 978 ) 922-6430 ?www.deltarf.com 22 bnc accessories (c) in contact plating column indicates captive contact. see page 4 for alternate body plating information. caps and terminations are available with other chain styles and/or resistances.
bulkhead jack?ack adapter (connects two plugs) dimensions max. mounting plating delta p/n abc panel figure body contact 1.53 .86 .69 .275 59 nickel silver ( c ) ug-492a/u * 1.53 .86 .69 .275 59 nickel silver ( c ) ug-492c/u * 1.53 .86 .69 .275 59 nickel silver ( c ) ug-492d/u * 1.53 .86 .69 .275 59 silver gold ( c ) m55339/13-00492 * 1.28 .80 .625 .160 59 nickel silver ( c ) 1026-000-n591 a b c dia. * hermetically sealed, with mounting gasket. a b panel mounted jack?ack adapter (connects two plugs) dimensions mounting figure plating delta p/n a b body contact 1.28 .69 07 nickel silver ( c ) ug-414a/u straight jack?ack adapter (connects two plugs) b dia. a dimensions plating delta p/n a b body contact 1.28 .44 nickel silver ( c ) ug-914/u 1.28 .44 silver gold ( c ) m55339/16-00914 1.28 .44 nickel gold ( c ) 1028-000-n001-3 delta electronics manufacturing ( 978 ) 927-1060 ?fax ( 978 ) 922-6430 ?www.deltarf.com 23 bnc adapters (c) in contact plating column indicates captive contact.
right angle and tee adapters straight plug?lug adapter (connects two jacks) 1.22 plating delta p/n body contact nickel silver ( c ) ug-491b/u silver gold ( c ) m55339/15-00491 figure dimensions plating delta p/n a b body contact 1 1.06 .88 nickel silver ( c ) ug-306a/u 1 1.06 .88 nickel silver ( c ) ug-306b/u 1 1.06 .88 silver gold ( c ) m55339/14-00306 1 1.06 .88 nickel gold ( c ) 1029-000-n000-3 2 1.28 1.03 nickel silver ( c ) ug-274a/u 2 1.28 1.03 nickel silver ( c ) ug-274b/u 2 1.28 1.03 nickel gold ( c ) ug-274c/u 2 1.28 1.03 silver gold ( c ) m55339/17-00274 3 1.28 .89 nickel silver ( c ) 1038-000-n000-2 3 1.28 .97 silver gold ( c ) m55339/17-00002 4 1.50 1.06 nickel silver ( c ) 1049-000-n000 4 1.50 1.06 silver gold ( c ) m55339/17-00001 a b a b a b a b straight plug?ack adapter (connects one jack and one plug) 1.25 plating delta p/n body contact nickel gold ( c ) 1034-000-n000 figure 1 (right angle plug?ack; connects one plug and one jack) figure 2 (tee jack?lug?ack; connects two plugs and one jack) figure 3 (tee jack?ack?ack; connects three plugs) figure 4 (tee jack?ack?lug; connects two plugs and one jack) delta electronics manufacturing ( 978 ) 927-1060 ?fax ( 978 ) 922-6430 ?www.deltarf.com 24 bnc adapters (c) in contact plating column indicates captive contact.
straight and right angle plugs for flexible cable cable figure dimensions plating delta p/n assembly procedure/ group a b body contact trim code 7 1 1.06 .50 nickel silver ( c ) 7501-019-n005 e/03 7 2 1.09 .50 nickel gold 7503-020-n000-2 b/19 7 2 1.05 .41 nickel gold ( c ) 7503-020-n001 b/26 7 3 1.03 1.71 nickel gold 7507-019-n000 b/02 9 1 1.06 .50 nickel silver ( c ) 7501-037-n005 e/03 9 2 1.13 .39 nickel gold 7503-037-n001 b/27 9 3 1.03 1.71 nickel gold 7507-037-n000 b/02 26 2 1.10 .45 nickel gold ( c ) 7503-108-n001 b/26 31 2 1.13 .50 nickel gold 7503-279-n001 b/19 b dia. a a b (crimp sleeve) figure 1 (heli-grip cable hardware) .50 (crimp sleeve) b a figure 2 (crimp type) figure 3 (crimp type) bulkhead jack?eli-grip for flexible cable cable fig. dimensions mounting max. plating delta p/n group abc figure panel body contact 7 1 1.16 .81 .50 59 .24 nickel gold ( c ) 7516-019-n595 e/03 9 1 1.16 .81 .50 59 .24 nickel gold ( c ) 7516-037-n595 e/03 figure 1 (rear mount) a b c dia. .687 hex assembly procedure/ trim code heli-grip cable attachment these connectors have captivated contacts and allow rapid, easy assembly?imply trim the cable, slide into the cone/insulator/contact assembly (left), solder the center conductor to the contact, and screw body assembly (right) onto cable assembly. delta electronics manufacturing ( 978 ) 927-1060 ?fax ( 978 ) 922-6430 ?www.deltarf.com 25 bnc75 cable connectors (c) in contact plating column indicates captive contact.
panel jack and plug receptacles?quare flange figure dimensions mounting plating delta p/n ab cd figure body contact 1 1.06 .63 .030 .090 09 nickel gold ( c ) 7513-000-n091 2 1.06 .63 .030 .080 33 nickel gold ( c ) 7513-000-n331-2 3 1.19 .80 .030 .090 18 nickel gold ( c ) 7523-000-n180 4 1.19 .80 .030 .080 33 nickel gold ( c ) 7523-000-n331-1 figure 1 (solder pot contact, 11 / 16 " square ?nge) a b d c ( i.d. ) figure 3 (solder pot contact, 3 / 4 " square ?nge) figure 4 (solder pot contact, 1" square ?nge, interchangeable with type n standard ?nge size) a b d c ( i.d. ) a b d c ( i.d. ) figure 2 (solder pot contact, 1" square ?nge, interchangeable with type n standard ?nge size) a b d c ( i.d. ) receptacles for printed circuit boards figure 1 figure 2 .687 sq. a c b .038 dia. typ. d dia. .500 typ. a c b d dia. .687 sq. .038 dia. typ. .500 typ. figure dimensions max. board mounting plating delta p/n ab cd thickness figure body contact 1 .65 .085 .250 .038 .125 pcb02 nickel gold ( c ) 7567-000-n13p-1 2 1.34 .52 .125 .038 .063 pcb02 nickel silver ( c ) 7569-000-n13p delta electronics manufacturing ( 978 ) 927-1060 ?fax ( 978 ) 922-6430 ?www.deltarf.com 26 bnc75 receptacles (c) in contact plating column indicates captive contact.
bulkhead jack receptacle figure dimensions mounting plating delta p/n ab cd figure body contact 1 1.06 .57 .030 .13 65 nickel gold ( c ) 7520-000-n651-1 2 1.06 .47 .030 .13 89 nickel gold ( c ) 7521-000-n621-2 figure 1 (d-hole mounting) figure 2 (round hole mounting) a b c ( i.d. ) d max. panel .500 dia. a b c ( i.d. ) d max. panel .468 hex bulkhead jack?ack adapter (connects two plugs) dimensions max. mounting plating delta p/n abc panel figure body contact 1.28 .80 .625 .16 59 nickel silver ( c ) 7526-000-n591 * 1.28 .80 .625 .16 59 nickel silver ( c ) 7526-000-n591-1 a b c dia. straight and right angle adapters figure dimensions plating delta p/n a b body contact 1 1.06 .88 nickel gold ( c ) 7529-000-n000 2 1.22 . nickel gold ( c ) 7527-000-n001 3 1.28 .44 nickel gold ( c ) 7528-000-n001 b dia. a a b a figure 1 (right angle plug?ack; connects one plug and one jack) figure 3 (straight jack?ack; connects two plugs) figure 2 (straight plug?lug; connects two jacks) delta electronics manufacturing ( 978 ) 927-1060 ?fax ( 978 ) 922-6430 ?www.deltarf.com 27 bnc75 receptacles/adapters (c) in contact plating column indicates captive contact. *isolated ground mounting.
delta electronics manufacturing ( 978 ) 927-1060 ?fax ( 978 ) 922-6430 ?www.deltarf.com 28 mounting figures connector flanges (panel mounted connectors) 4-hole ?nges figure ab c 04 1 / 2 .360 .089 05 1 / 2 .340 .102 07 11 / 16 .500 #3-56 tap 08 11 / 16 .500 .136 09 11 / 16 .500 .125 10 11 / 16 .500 .120 12 11 / 16 .500 .109 18 3 / 4 .531 .136 26 1 .718 #6-32 tap 27 1 .718 #4-40 tap 30 1 .718 .166 32 1 .718 .136 32a 1 .718 .136* 33 1 .718 .125 34 1 3 / 32 .812 .150 36 1 3 / 16 .906 #6-32 tap 39 1 3 / 16 .906 .152 40 1 3 / 16 .906 .125 45 2 1.437 .257 91 .375 .250 .067 91a .375 .232 .093 a square c dia. typ. b ( l ) typ. c a d dia. typ. b ( l ) c c * countersunk to .245 dia. 2-hole ?nges figure abcd 92 .223 .481 .625 .102 92a .260 .481 .625 .102 95 .640 1.015 1.30 .125 panel cutouts (bulkhead mounted connectors) d-hole figure a b 51 .755 .723 54 .630 .598 55 .630 .583 57 .557 .531 59 .505 .473 62 .442 .410 63 .407 .362 65 .380 .348 66 .319 .292 67 .255 .236 68 .195 .176 double d-hole figure a b 69 .755 .692 72 .630 .536 75 .380 .341 84 .319 .278 b a dia. b a dia. round hole figure a 82 .255 89 .380 a dia. p.c. board drilling twinax connectors figure a b c d pcb04 .045 .500 .250 .045 a dia. typ. d dia. b ( l ) typ. c c ( l ) typ. c a dia. typ. .0625 typ. d dia. typ. b ( l ) typ. c c ( l ) typ. c .125 ( l ) c coaxial connectors figure abcd pcb01 .067 .400 .200 .045 pcb02 .045 .500 .250 .045 pcb03 .067 .300 .150 .035 pcb05 .067 .200 .100 .055 pcb06 .067 .200 .100 .045 (pcb traces are shown for illustrative purpose only, and are not representative of actual circuitry.) (pcb traces are shown for illustrative purpose only, and are not representative of actual circuitry.)
delta electronics manufacturing ( 978 ) 927-1060 ?fax ( 978 ) 922-6430 ?www.deltarf.com 29 cable groups delta cable groups group cables 1a rg-5, 5a, 5b, 21, 21a; m17/73, /162 1 1b rg-6, 6a; m17/2 1c rg-143, 143a, 212, 222; m17/73, /112, /162 2 2a rg-8, 8a, 213; m17/74 2b rg-11, 11a; m17/6 3a rg-9, 9a, 9b, 214; m17/75 3 3b rg-13a, 216; m17/77 3c rg-225; m17/127 4 rg-393; m17/127 5 rg-58, 58a, 58c, 141, 141a; m17/28, /111 6 6a rg-55a, 142, 142a, 223, 400; m17/60, /84, /128 6b rg-55, 55b, 142b; m17/60, /84 7 7a rg-59, 59a, 59b, 62, 62a, 62b, 62c, 210; m17/29, /30, /97 7b rg-71, 71a, 71b; m17/90 8 8a rg-122; m17/54 8b rg-180, 180a, 180b, 195; m17/95, /137 9 9a rg-174, 188, 188a, 316; m17/152 9b rg-179a, 179b, 187, 187a; m17/94, /136 10 double-shielded rg-174, 316; m17/152 11 rg-178, 178a, 178b, 196, 196a; m17/93 12 .250" semi-rigid; rg-401; m17/129 13 .141" semi-rigid; rg-402; m17/130 14 .085" semi-rigid; rg-405; m17/133 15 rg-10, 12, 215; m17/6, /74 16 rg-14a, 217; m17/78, /165 17 rg-17a, 218 18 rg-18a, 219 19 rg-115a 20 rg-118a, 228a 21 rg-126 22 rg-302 23 rg-303 24 rg-304 25 special 8x cable; contact factory for details. 26 belden 8281 27 rg-108, 108a; m17/45 28 rg-22, 22a, 22b; m17/15 29 belden 9207; dearborn 6207; ibm 7362211 30 m17/176 31 at&t 735a rg-5, 5a, b 1a rg-6, 6a 1b rg-8, 8a 2a rg-9, 9a, b 3a rg-10 15 rg-11, 11a 2b rg-12 15 rg-13a 3b rg-14a 16 rg-17a 17 rg-18a 18 rg-21, 21a 1a rg-22, 22a, b 28 rg-55, 55b 6b rg-55a 6a rg-58, 58a, c 5 rg-59, 59a, b 7a rg-62, 62a, b, c 7a rg-71, 71a, b 7b rg-108, 108a 27 rg-115a 19 rg-118a 20 rg-122 8a rg-126 21 rg-141, 141a 5 rg-142, 142a 6a rg-142b 6b rg-143, 143a 1c rg-174 9a rg-174ds 10 rg-178, 178a, b 11 rg-179a, 179b 9b rg-180, 180a, b 8b rg-187, 187a 9b rg-188, 188a 9a rg-195 8b rg-196, 196a 11 rg-210 7a rg-212 1c rg-213 2a rg-214 3a rg-215 15 rg-217 16 rg-218 17 rg-219 18 rg-222 1c rg-223 6a rg-225 3c rg-228a 20 rg-302 22 rg-303 23 rg-304 24 rg-316 9a rg-316ds 10 rg-393 4 rg-400 6a rg-401 12 rg-402 13 rg-405 14 m17/2 1b m17/6 2b m17/15 28 m17/28 5 m17/29 7a m17/30 7a m17/45 27 m17/73 1a m17/162 1a m17/112 1c m17/74 2a m17/75 3a m17/127 3c m17/77 3b m17/60 6a m18/84 6a m17/128 6a m17/97 7a m17/54 8a m17/95 8b m17/137 8b m17/152 9a m17/93 11 m17/129 12 m17/130 13 m17/133 14 m17/78 16 m17/165 16 m17/176 30 at&t 735a 31 belden 8281 26 belden 9207 29 dearborn 6207 29 ibm 7362211 29 cable group finder cable group cable group
delta electronics manufacturing ( 978 ) 927-1060 ?fax ( 978 ) 922-6430 ?www.deltarf.com 30 assembly procedures assembly procedure a 1) trim cable jacket to dimension a. slide backnut, washer, v-gasket, and braid clamp onto cable as shown. cable jacket should bottom on step in braid clamp. 2) comb braid wires out straight and fold back over front shoulder of braid clamp (braid wires should not overlap one another after folding). trim braid wires ?sh with step of braid clamp. trim cable dielectric and center conductor to dimensions b and c. 3) if support insulator is provided for rg-62 or 71 cable, insert into hollow in dielectric. assemble rear bushing or washer (if supplied), rear insulator (if captive contact) and contact, and solder contact to center conductor. rear of contact should be ?sh with cable dielectric end. for right angle connectors with access cap, omit this step entirely. 4) insert prepared cable and hardware into body and tighten backnut. for right angle connectors with access cap, solder center conductor into slot in contact and tighten access cap. code a b c a/01 .375 (3/8) .047 (3/64) .203 (13/64) a/02 .375 (3/8) .109 (7/64) .203 (13/64) a/03 .438 (7/16) .250 (1/4) .188 (3/16) a/04 .281 (9/32) .047 (3/64) .125 (1/8) a/05 .313 (5/16) .125 (1/8) .109 (7/64) a/06 .594 (19/32) .391 (25/64) .156 (5/32) a/07 .375 (3/8) .047 (3/64) .125 (1/8) a/08 .281 (9/32) .109 (7/64) .094 (3/32) a/09 .344 (11/32) .109 (7/64) .094 (3/32) a/10 .406 (13/32) .109 (7/64) .203 (13/64) a/11 .500 (1/2) .281 (9/32) .156 (5/32) a/12 .343 .040 .219 a/13 .375 (3/8) .125 (1/8) .156 (5/32) a/14 .355 .090 .188 (3/16) a/15 .425 .094 (3/32) .259 a/16 .328 (21/64) .094 (3/32) .188 (3/16) a/17 .375 (3/8) .109 (7/64) .125 (1/8) a/18 .375 (3/8) .062 (1/16) .172 (11/64) a/19 .375 (3/8) .188 (3/16) .094 (3/32) code a b c a/20 .375 (3/8) .047 (3/64) .172 (11/64) a/21 .500 (1/2) .313 (5/16) .172 (11/64) a/22 .375 (3/8) .188 (3/16) .141 (9/64) a/23 .438 (7/16) .078 (5/64) .172 (11/64) a/24 .500 (1/2) .094 (3/32) .141 (9/64) a/25 .438 (7/16) .141 (9/64) .172 (11/64) a/26 .625 (5/8) .281 (9/32) .250 (1/4) a/27 .688 (11/16) .281 (9/32) .125 (1/8) a/28 .656 (21/32) .297 (19/64) .250 (1/4) a/29 .688 (11/16) .125 (1/8) .313 (5/16) a/30 .688 (11/16) .469 (15/32) .156 (5/32) a/31 .700 (21/32) .453 (29/64) .250 (1/4) a/32 .313 (5/16) .078 (5/64) .188 (3/16) a/33 .250 (1/4) .078 (5/64) .094 (3/32) a/34 .250 (1/4) .062 (1/16) .109 (7/64) a/35 .837 .575 .150 a/36 .450 .250 .150 a/37 .281 .038 .188 a/38 .281 .069 .156 trim codes for assembly procedure a backnut washer (if supplied) v-gasket braid clamp a washer and/or bushing (if supplied) contact (non-captive) or contact (captive) & insulator fold braid over b c non-captive contact solder solder captive contact washer or bushing (if supplied)
delta electronics manufacturing ( 978 ) 927-1060 ?fax ( 978 ) 922-6430 ?www.deltarf.com 31 assembly procedures assembly procedure b crimp sleeve contact (captive) contact (non-captive) solder a or b c 1) trim cable per chart. slide crimp sleeve back onto cable. 2) if support insulator is provided for rg-62 or 71 cable, insert into hollow in dielectric. solder con- tact onto center conductor; back of contact ?sh with trimmed end of cable dielectric (omit this step for right angle connectors with access caps). flare cut end of braid slightly by rotating dielectric. 3) insert cable/contact into rear of body, with all braid wires on outside of crimp tail. a) for captive contact connectors, push cable in until contact snaps into insulator. b) for noncaptive contact connectors, push cable in until cable dielectric bottoms in connector. c) for right angle or tee connectors with access caps, push cable in until end of braid touches connector body shoulder, and cable center conductor rests in contact slot. trim excess braid wires even with shoulder of body. slide crimp sleeve forward until ?sh with body and crimp (see page 176 for hex die sizes). for right angle or tee connectors with access caps: solder center conductor into contact slot, assemble insulator disc (if supplied), then press cap into body until seated or screw into place. code a b c b/01 .320 .470 .140 b/02 .422 .578 .172 b/03 .406 .500 .187 b/04 .285 .505 .140 b/05 .335 .460 .140 b/06 .187 .437 .219 b/07 .422 .610 .156 b/08 .422 .562 .219 b/09 .313 .610 .203 b/10 .280 .436 .187 b/11 .430 .542 .156 b/12 .300 .434 .156 b/13 .300 .447 .156 b/14 .420 .645 .187 b/15 .300 .420 .120 b/16 .312 .609 .125 b/17 .250 .500 .156 b/18 .437 .562 .109 b/19 .343 .437 .156 code a b c b/20 .250 .375 .156 b/21 .425 .550 .156 b/22 .375 .500 .156 b/23 .281 .469 .125 b/24 .250 .700 .109 b/25 .343 .775 .125 b/26 .343 .437 .109 b/27 .313 .437 .187 b/28 .219 .271 .078 b/29 .200 .320 .060 b/30 .500 .650 .219 b/31 .350 .840 .150 b/32 .175 .260 .095 b/33 .195 .270 .045 b/34 .150 .250 .105 b/35 .195 .280 .170 b/36 .150 .325 .090 b/37 .195 .295 .075 b/38 .150 .225 .095 b/39 .250 .300 .135 trim codes for assembly procedure b
delta electronics manufacturing ( 978 ) 927-1060 ?fax ( 978 ) 922-6430 ?www.deltarf.com 32 assembly procedures assembly procedure c backnut washer gasket braid clamp contact (captive) & insulator contact (non-captive) fold braid over non-captive captive solder a b c or 1) trim cable jacket to dimension a. slide backnut, washer, gasket, and braid clamp onto cable as shown. cable jacket should bottom on step in braid clamp. 2) comb braid wires out straight and fold back over front shoulder of braid clamp (braid wires should not overlap one another after folding). trim braid wires ?sh with edge of braid clamp. trim cable dielectric and center conductor to dimensions b and c. 3) if support insulator is provided for rg-62 or 71 cable, insert into hollow in dielectric. assemble rear insulator (if captive contact) and contact, and solder contact to center conductor. rear of contact should be ?sh with cable dielectric end. 4) insert prepared cable and hardware into body and tighten backnut. for right angle connectors with access cap, solder cable center conductor to slot in contact and tighten access cap. trim codes code a b c c/01 .656 (21/32) .141 (9/64) .250 (1/4) c/02 .500 (1/2) .125 (1/8) .250 (1/4) c/03 .450 .136 .187 c/04 .375 (3/8) .109 (7/64) .125 (1/8) c/05 .375 (3/8) .062 (1/16) .250 (1/4) c/06 .500 (1/2) .188 (3/16) .125 (1/8) c/07 .575 .438 .094 c/08 .625 (5/8) .141 (9/64) .219 (7/32) assembly procedure e backnut contact/insulator/ cone grip assembly solder a b c 1) slide backnut onto cable as shown. trim cable to dimen- sions a and b as shown. slit jacket to dimension c in two places, 180 apart. 2) slide cone/insulator/contact assembly under braid until braid is ?sh with shoulder. solder contact to center conductor. 3) insert prepared cable and hardware into body; tight- en assembly by holding nut stationary and turning body. trim codes code a b c e/01 .250 (1/4) .141 (9/64) .313 (5/16) e/02 .219 (7/32) .063 (1/16) .250 (1/4) e/03 .250 (1/4) .031 (1/32) .250 (1/4)
delta electronics manufacturing ( 978 ) 927-1060 ?fax ( 978 ) 922-6430 ?www.deltarf.com 33 assembly procedures frame only?/n m22520/5-01 ?se with interchangeable dies listed below. for cable group(s) hex die size die set p/n closure 2, 3, 4 .429 hex, .400 wide m22520/5-61 a 5, 6 .213 hex, .400 wide m22520/5-19 b 7 .255 hex, .400 wide m22520/5-19 a 9 .128 hex, .400 wide m22520/5-35 b 10 .151 hex, .400 wide m22520/5-37 b 11 .105 hex, .400 wide m22520/5-33 b m22520/5-01 crimp tools for flexible cable assembly procedure f backnut washer v-gasket solder ferrule contact (captive), insulator, & bushing contact (non-captive) non-captive captive solder a or b solder solder 1) trim cable per chart. slide backnut, washer, v-gasket, and solder ferrule onto cable. trimmed end of cable jacket should bottom on step in solder ferrule. 2) solder ferrule to cable jacket as shown. retrim cable dielectric to proper length if it has extruded from soldering heat. slide bushing and rear insulator over cable dielectric if captive contact. solder contact onto center conductor; back of contact ?sh with trimmed end of cable dielectric. trim codes code a b f/01 .250 (1/4) .219 (7/32) f/02 .250 (1/4) .172 (11/64) f/03 .188 (3/16) .188 (3/16) f/04 .109 (7/64) .265 (17/64) f/05 .156 (5/32) .250 (1/4) f/06 .219 (7/32) .250 (1/4) f/07 .156 (5/32) .172 (11/64) f/08 .109 (7/64) .219 (7/32) 3) insert prepared cable and hard- ware into body and tighten backnut.
delta electronics manufacturing ( 978 ) 927-1060 ?fax ( 978 ) 922-6430 ?www.deltarf.com 34 warranty we warrant our parts to be free from defects in materials and workmanship for one year from date of purchase. during that time, we will repair or replace (at our option) any parts found to be defective. this warranty does not apply to parts which have been modi?d, used in conditions exceeding delta or military speci?ations, or disassembled. we will not, under any circumstances, be responsible for consequential or incidental damages or installation costs. no other warranties apply, and no other liability may be assumed or extended by representatives or distributors. returns returns will be accepted only with a return authorization number issued by delta, and are subject to inspection and acceptance upon arrival. restocking charges will be determined prior to issuance of return authorization. all claims for shortages must be made within 30 days of receipt by customer. ordering information orders are subject to the terms and conditions on our order acknowledgement, which may only be modi?d by written agreement prior to sale. order changes, cancellation, or termination will be accepted only with written approval from delta electronics manufacturing. copyright, trademarks, and patents entire contents copyright 2003, delta electronics manufacturing corporation. reproduction rights are hereby granted for, and speci?ally limited to, printing or other reproduction of drawings and speci?ations for inclusion in speci?ation or source control drawings, or for purchasing procedures, by delta customers only. heli-grip , pressmount , and the new england craftsmanship logo are trademarks. the heli-grip design is covered by u.s. and foreign patents. delta electronics manufacturing corporation 416 cabot street, p.o. box 53 beverly, ma 01915 fscm/cage 00795 catalog # bncpdf2003 1.0 ordering and warranty information