 SGX-41F
SOLID STATE RELAY 4 AMPS 48 TO 400 VRMS
FEATURES * * * * * * * * Photo isolation Up to 800V blocking voltage Both zero cross or random turn-on High surge capability Built-in snubber UL, CUR file E43203 SCR or Triac Output Circuitry RoHS compliant
INPUT Type
Control Voltage Range Turn On Voltage Turn Off Voltage Max. Input Current Max. Reverse Voltage 1D 3 to 15 VDC 3 VDC max. 1 VDC min. 40 mA at 15 VDC -15 VDC 2D 15 to 32 VDC 15 VDC max. 1 VDC min. 20 mA at 32 VDC -32 VDC
OUTPUT
Type Output Voltage Range Blocking Voltage Max. Leakage Current (off) Max. Voltage Drop (at rated current) Min. Load Current Max. Turn-On Time 240 48 to 264 VAC 600 Vpk 5 mA 1.7 VRMS 100 mA Random Turn On (DC input): 1 ms Zero Cross Turn On (DC input): 1/2 cycles + 1 ms AC Input: 20 ms DC Input: 1/2 cycle + 1 ms AC Input: 40 ms Triac: 200 V/us / SCR: 500 V/us 380 48 to 400 VAC 800 Vpk 5 mA
Max. Turn-Off Time
Min. Off-State (dv/dt)
GENERAL
Dielectric Strength Insulation Resistance Ambient Temperature 4000 Vrms min. (at 50/60 Hz, 1 min.) 1000 Min. (at 500 VDC) Operating: -30C (-22F) to 80C (176F) Storage: -30C (122F) to 100C (212F) Termination Weight PCB 15g
3/29/06W
SGX-41F
RELAY ORDERING DATA SGX-41F
MODEL
1D
INPUT VOLTAGE 1D: 3 TO 15 Vdc 2D: 15 to 32 Vdc
240
OPERATING VOLTAGE RANGE 240:48 TO 264 Vac 380: 48 to 400 Vac
A
LOAD TYPE A: AC LOAD
4
LOAD CURRENT 4: 4A
Z
S
G
PACKAGE G: epoxy
ZERO CROSS OUTPUT DEVICE OR RANDOM Z: Zero cross turn on P: Random turn on S: SCR Nil: Triac
MECHANICAL DATA
Outline Dimensions PC Board Layout
1.724MAX [43.8]
.374MAX [9.5]
.100 [2.54] .200 [5.08]
O0.047 [1.2]
1.043MAX [26.5MAX]
.118MAX [3.0]
0.200 [5.1] .370 [9.4]
.201 [5.1] O.039 [1.0]
0.700 [17.8] 1.100 [27.9]
.701 [17.8] 1.098 [27.9]
.098MAX [2.5]
Wiring Diagram
-4
+3
2
1
Load Input control Power supply
Dimensions in inches with metric equivalents in parentheses. Tolerance: .010"
INSTALLATION
1. When mounting the relays side by side, provide a space equivalent to the width of a single SSR between two adjacent SSRs. Otherwise, reduce the load current flow to 1/2 to 1/3 of the rated current.
PRECAUTIONS
1. Before connecting a load that generates a high surge current, such as a lamp load to the SSR, make sure that the SSR can withstand the surge current of the load. The product data sheet shows the non-repetitive peak value of the surge current that flows through the SSR. Normally, use 1/2 of the non-repetitive peak surge current as the standard value. If a surge current exceeding that value is expected, connect a quick-blowing fuse to protect the SSR.
2.
3/29/06W
SGX-41F
CHARACTERISTIC CURVES
Figure 1 Maximum load current vs. ambient temperature
3/29/06W


▲Up To Search▲   

 
Price & Availability of SGX-41F1D240A4PSG

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X